DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-561DUPINT (Duplication Interface Circuit Pack)
10
pack responds to this query, then the reset passes. If performed on Duplication
Interface A, this test can cause an SPE interchange to the SPE in the B carrier if
the A carrier SPE was active when the test was executed. The B carrier
Tone-Clock circuit pack is also selected on Duplication Interface circuit pack A
processor reset. This test is run only when demanded by software and can be
performed on either Duplication Interface circuit pack. There is no
service-disruption when this test is run on Duplication Interface B.
Table 10-189. TEST #273 Duplication Interface Circuit Pack
Sanity Circuit Test
Error
Code
Test
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1037 ABORT The active Tone-Clock circuit pack is currently the one in the A carrier. If
the Duplication Interface circuit pack is allowed to be reset at this time, an
unscheduled tone/clock switch would take place resulting in a Cold 2
restart.
1. Check for alarms against TONE-BD in the B carrier and refer to
TONE-BD (Tone-Clock Circuit Pack) to resolve these alarms.
2. When there are no alarms against TONE-BD in the B carrier, force the
-one-Clock circuit pack to be active by issuing the set tone-clock b
command.
3. Verify the B carrier Tone-Clock circuit pack is active by using the
status system command.
4. Rerun the Duplication Interface circuit pack test.
1185 ABORT Only occurs when attempting to reset Duplication Interface A when SPE A
is active and SPE A has not been selected by the SPE Select switch. In this
case, resetting Duplication Interface A causes a warm start
SPE-interchange to SPE B.
1. Issue the reset system interchange command to make SPE A the
Standby SPE.
2. Repeat the test.
2018 ABORT Applicable only when testing Duplication Interface A. (1) Refer to
STBY-SPE (Standby SPE) Maintenance documentation for a description of
this error.
2033 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page