Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-324test analog-testcall
8
Feature Interactions
Additional data is available after running a test. See the ‘‘list
measurements’’ command with the
test-call
option for details on how to
access the additional data.
If the trunk is in use by call processing, the test aborts.
If the trunk is in use by maintenance, the test queues and runs when the
current maintenance activity finishes.
Output
The following example shows the output for the test analog-testcall trunk 78
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field descriptions
Port The port address (cabinet-carrier-slot-circuit) of the maintenance
object that is being tested.
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name Alternate way to identify maintenance objects.
If the Object is The field contains
trunk
xxx/yyy
(where
xxx
= trunk group number
and
yyy
= member number)
Test No. The test being executed
Result Test result: Pass, Fail, Abort, Disabled, No Board, or Extra Board.
Error Code Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test analog-testcall trunk 78
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1505 CO-TRK 78/1 845 PASS
01C1507 CO-TRK 78/2 845 PASS
Command Successfully Completed