Page 10-595ETR-PT (Enhanced Tone Receiver Port)
10
1002 ABORT The system could not allocate time slots for the test connection. This
situation could occur when the system is heavily loaded. If the system is
not heavily loaded, then test the TDM-BUS via the test tdm command.
Refer to TDM-BUS for details.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a Tone-Clock for the test connection. This
may be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the port
network where the test aborted. If so refer to the recommended
procedures for TONE-BD or TONE-PT.
2. If a new Tone-Clock has been inserted, allow about 1 minute for
maintenance to run on the newly inserted circuit pack.
3. Retry the command at 1-minute intervals a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
2000 ABORT Circuit Pack’s response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2006 ABORT This abort code indicates that the active Tone-Clock circuit pack or a Tone
Detector circuit pack may not be functioning properly. On G3r V2 systems,
this abort can also be caused by a mismatch between the companding
mode administered for the system and that of the Tone Detector circuit
pack.
1. [G3r V2] Make sure that the companding mode of the system matches
that of the Tone Detector: mu-law for TN748; A-law for TN420.
2. Test the
active
Tone-Clock circuit pack in the port network with the
test tone-clock PC command and refer to the TONE-BD section for
failures.
3. Retry the command at 1-minute intervals a maximum of five times.
4. If the test continues to abort, escalate the problem.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
Table 10-205. TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page