DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1448UDS1-BD (UDS1 Interface Circuit Pack)
10
Table 10-489. System Technician-Demanded Tests: Descriptions and Error Codes
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence
test ds1-loop
Command D/ND
1
NPE Connection Audit
Test (#50)
XND
Control Channel Loop Test
(#52)
XND
Loss of Signal Alarm
Inquiry Test (#138)
XX ND
Blue Alarm Inquiry Test
(#139)
XX ND
Red Alarm Inquiry Test
(#140)
XX ND
Yellow Alarm Inquiry Test
(#141)
XX ND
Major Alarm Inquiry Test
(#142)
XX ND
Minor Alarm Inquiry Test
(#143)
XX ND
Slip Alarm Inquiry Test
(#144)
XX ND
Misframe Alarm Inquiry
Test (#145)
XX ND
Translation Update Test
(#146)
XX ND
ICSU Status LEDs Test
(#1227)
XX ND
SAKI Sanity Test (#53) X D
Internal Loop Around Test
(#135)
XD
DS1/CSU Loopback Tests
DS1 Board Loopback Test
(#1209)
XD
CSU Equipment Loopback
Test (#1210)
XD
CSU Repeater Loopback
Test (#1211)
XD
CPE Loopback Jack Test
(#1212)
XD
Continued on next page