Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1270TAPE-DAT (Tape Consistency)
10
64 FAIL The update files are different in both SPEs. The update file on the standby
SPE is most current.
1. If you are on site with the switch, interchange the Active SPE tape with
the Standby SPE tape. If you are not on site with the switch, issue the
reset system interchange command. This action causes the Standby
SPE to become the Active SPE. Refer to the "Reset Commands" section
in Chapter 8 for information on the side effects of a processor
interchange.
2. Have INADS issue the copy update-file command. If the update file
copy passes, proceed to Step 3.
3. Reissue the test tape long command to resolve the alarms.
65 FAIL The update files and translations are different in both SPEs. The Standby
SPE has the most current update file, and the Active SPE has the most
current translations.
66 FAIL The update files and translations are different in both SPEs. The Standby
SPE has the most current update file and translations.
1. Issue the save translations command to save translations on both
SPEs.
2. Follow the procedures for Error Code #64.
68 FAIL The update files and load vintages are different in both SPEs. The Standby
SPE has the most current update file.
69 FAIL The update files, load vintages, and translations are different in both SPEs.
The Standby SPE has the most current update file, and the Active SPE has
the most current translations.
70 FAIL The update files, load vintages, and translations are different in both SPEs.
The Standby SPE has the most current update file and translations.
1. Follow the procedures for Error Code #4 to get the correct load
vintage. After running the test tape long command, check for Error
Code #32 or #64. Follow the recovery procedure under the applicable
error code.
72 FAIL The update files and announcements are different in both SPEs. The
Standby SPE has the most current update file and the Active SPE has the
most current announcements.
1. Issue the save announcements command to save announcements on
both SPEs.
2. Follow the procedures for Error Code #64.
Table 10-437. TEST #421 Tape Data Consistency Check Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page