DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-342test eda-external-device-alrm
8
Output
The following example shows the output for the test external-device-alarm all
command. The responses display on a test-by-test basis with one line of data for
each test result.
Field definitions
Port Port address (cabinet-carrier-slot-circuit)
Maintenance Name The name of maintenance object
Alt. Name The alternate means of identifying the maintenance object, in
this case, the administered (descriptive) name of the external
device alarm.
Test No The test being executed
Result Test result: Pass, Abort, Fail, No Board, Disabled, or Extra Bd.
Error Code Numeric code explaining why the release failed or aborted.
Refer to the detailed list of the codes by test number for each
MO.
test eda-external-device-alrm all
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
03major EXT-DEV CMS1 120 PASS
03A2102 EXT_DEV CMS2 120 FAIL
01major EXT-DEV UPS1 120 PASS
01minor EXT-DEV UPS1 120 PASS
01c1201 EXT-DEV UPS1 120 PASS
03A2101 EXT_DEV CC temp 120 PASS
01c1202 EXT-DEV Audix1 120 PASS
03minor EXT-DEV Audix2 120 FAIL
04major EXT-DEV unknown 120 FAIL
Command successfully completed