Maintenance Object Repair Procedures
Page 10-1045PR-MAINT (Maintenance Processor [TN790 RISC Systems])
10
MTP Sanity Handshake Test (#106)
This test is a nondestructive test. The MTP Sanity Handshake Test is simply a
query from a maintenance process to the MTP. The MTP must reply for the test to
pass.
MTP SAT Loop Around Test (#228)
This test is a nondestructive test. The test places the SAT channel of the MTP into
a loop around mode, and it verifies the data integrity of the channel. Although the
test is nondestructive, it causes loss of keyboard input from the PPN SAT.
Table 10-358. TEST #106 MTP Sanity Handshake Test
Error Code
Test
Result Description/ Recommendation
100 ABORT The test did not complete within the allowable time period.
1. Retry the command.
1000 ABORT System software resources required for this test are not available.
1. Retry at 1-minute intervals a maximum of 5 times.
1029 2014
2015 2016
2017 2018
2020 2022
2024 2025
2051
ABORT Refer to “STBY-SPE” for a description of these error codes.
2000 ABORT The response to the test request was not received within the allowable
time period.
2033 ABORT Internal system error.
1. Repeat the command at 1-minute intervals a maximum of 5 times.
FAIL The MTP did not respond to the Sanity Handshake Query.
1. Re-enter command with the ‘‘long’’ option.
2. If the test continues to fail, replace the Processor circuit pack.
PASS The MTP responded to the Sanity Handshake Query.