Maintenance Object Repair Procedures
Page 10-203BRI-SET, ASAI-ADJ, BRI-DAT
10
1187 ABORT The circuit pack, port or station may have been busied out by
a technician.
1. Look in the Error Log for Error Type 18 (busied out ) for
BRI-BD, BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then release
the station via the release station command.
a. If this error type is present for BRI-PORT and BRI-SET,
then release the port via the release port PCSSpp
command and run the test again.
b. If the error is present for BRI-BD, BRI-PORT, and
BRI-SET, then release the circuit pack via the release
port PCSSpp command and run the test again. If the
error is present for BRI-SET only, then release the
circuit pack via the release port PPCSS command
and run the test again. If the error is present for both
BRI-BD and BRI-PORT, then release the circuit pack
via the release board PPCSS command and run the
test again.
NOTE:
When you release the circuit pack, you
release all ports associated with it. If certain
ports still need to be busied out, use the
release port PCSSpp command to busy
them out.
3. Make sure the terminal is connected.
4. Retry the command at one-minute intervals a maximum of
five times.
5. If the test continues to abort, escalate the problem.
2012 ABORT Internal System Error.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals a maximum of
five times.
2. If the test continues to abort, escalate the problem.
Table 10-72. TEST #629 BRI Layer 3 Query — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page