Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-43disable mst
8
disable mst
This command stops the message trace facility. If the trace was not already
disabled, the command inserts a GAP marker into the trace. The user should
execute the disable mst command when the trace is complete. If left enabled,
the trace continues to use CPU time until the time limit expires. Entering disable
mst command has no effect on the system if the trace is already disabled. To
view the results of the trace, enter the list mst command.
disable suspend-alm-orig
This command stops entries from the active Suspend Alarm Origination table.
This command disables all board entries that match a specific physical board
location.
NOTE:
This command does
not
disable
port entries.
disable synchronization-switch
This command stops the automatic clock switching capability of the maintenance
subsystem. The clock refers to the oscillator on a tone/ clock or DS1 interface.
The synchronization subsystem (TDM bus clock, DS1 trunk board, and
maintenance and administration software) provides error-free digital
communication between the switch and other PBXs, COs, or customer
equipment.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
disable mst Example:
disable mat
init
inads
none none
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
disable
suspend-
alm-orig
board
location
Physical location of the replaced or
corrected board (does not
support port location): PCss
Examples:
disable suspend-alm-orig 1C03
disable suspend-alm-orig 1E07
init
inads
craft
cust
rcust
none none
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
disable
synchronization-
switch
init
inads
craft
none none