DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-169recycle carrier
8
Feature Interactions
Carrier “a” cannot recycle its power. When carrier “b” of the PPN contains SPE
duplication hardware, it cannot recycle its power.
Recycling maintenance objects results in:
The test tdm command accelerates retirement of these problems.
Output
The following output example displays the recycle carrier c command.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout mis
location
Physical location of desired
carrier.
Carrier b-e. (b not applicable
for SPE duplex PPNs)
init
inads
craft
cabinet = 1
none for
carrier
see below
Recycled component Result
Port Carriers
Interrupted service
Carriers with active
EIs
Disrupted communication with that cabinet
Carriers with active
tone-clock boards
Interrupted service for ports port network
Carrier
The list configuration command causes circuit packs
to display red LEDs and NO BOARDs.
recycle carrier c
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C CARR-POW 126 PASS
Command successfully completed