Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-209set signaling-group
8
PMS log printer (PMS-LOG)
Primary CDR Link (PRI-CDR)
Secondary CDR Link (SEC-CDR)
SPE Select Switches (SPE-SELEC)
Synchronization (SYNC)
System Communication Interface (PI-SCI)
System Printer (SYS-PRNT)
TDM Clock (TDM-CLK)
Tone Generator Circuit Pack (TONE-BD)
set signaling-group
This command upgrades secondary D-channel in specified signaling groups to
primary D-channels. Current primary D-channel then revert to secondary
D-channels.
A signaling group is a collection of B-channels that designate single D-channels
or a set of D-channels signals over an ISDN-PRI.
set synchronization
This command sets DS1 trunks or active tone/clock circuit packs that supply
references for synchronization. The set synchronization command works after
the disable synchronization command disables synchronization. Technicians
may administer DS1 trunks or active tone/clocks with the set synchronization
command. DS1 or tone/clocks remain synchronization references until the set
synchronization command runs with another board or until the enable
synchronization command runs.
After the enable synchronization command runs, administered primary or
secondary synchronization sources become synchronization references. If no
primary or secondary source is administered, synchronization uses active
tone/clock boards as synchronization references after synchronization is
enabled.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
set
signaling-group
group
identifier
administered number associated
with each signaling group.
Examples:
set signaling-group 1
set signaling-group 2
init
inads
craft
none none