DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-44list measurements
A
list measurements
Help Messages
If the system technician presses HELP after entering "list measurements ds1", the
following list of options is displayed:
log summary
If the system technician presses HELP after entering "list measurements ds1 log" or "list
measurements ds1 summary", the following message is displayed:
Enter board location: [cabinet(1-3)];carrier(A-E);slot(00-20),
[’print’ or ’schedule’]
Error Messages
If the user enters an invalid format for a board location when entering a "list
measurements ds1 log" or "list measurements ds1 summary" command, the following
error message is displayed:
"entered value" Invalid slot address for DS1 board
If the user enters a board location that is not a DS1 board location or the location of an
unadministered DS1 when entering a "list measurements ds1 log" or "list measurements
ds1 summary" command, the following error message is displayed:
DS1 board has not been administered
If the user enters anything other than "log" or "summary" following "list measurements
ds1", the following error message is displayed:
"entered value" is an invalid entry; please press HELP
If the system time has not been set correctly, after entering "list measurements ds1 log
ds1_location" or "list measurements ds1 summary ds1_location" the following error
message is displayed:
Cannot get time from system clock
list mst
Help Messages
If the user presses HELP after entering "list mst" the following message will be displayed:
Enter [ ’from’ 0-32767 ] [ ’count’ 1-9998 ]
[ ’fifo’ or ’lifo’ or ’continuous’ ]