DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-958PI-LINK (Processor Interface Link)
10
.
1, 2 System error.
7 System error. If this error is occurring on all administered
links with the same Aux Data and all links are alarmed, then
execute the reset interface command to restore all the
links.
12 One of the two Loop Around Tests failed (#182 or #183).
See the "Link Recovery" section.
13 Hardware problem with DS1 facility is affecting ISDN links.
Refer to DS1-BD Maintenance documentation.
19 A transient state associated with the D-channel backup
protocol. The link is being held in the busy state until call
control can be moved to the new active link. No action
needs to be taken.
32771
32772
The remote endpoint indicates that the call is up and the
local PBX cannot complete the call. Check trunk status (on
the remote end and local end) if a DS1 trunk is used, or
check the status of the data module if a data module is
used in the link. The commands are status trunk trk-grp/
member or status data-module <ext>. If the destination is
in-service/active, then the commands are busyout trunk
trk-grp/member and release trunk trk-grp/member (on
both sides of the link if this is a DCS link). If a data module
is used in the link, then use a busyout data-module <ext>
command followed by a release data-module <ext>
command. Busy out the Processor Interface Link prior to
busying the trunk or data module. Release the Processor
Interface Link via release link lnk-no command and the
Processor Interface Link re-starts. If this fails, check the
status of the TN765 port using status data <ext> where
<ext> is the extension of the port from the interface
extension in the Display Communication Link form; if the
state is "in-service/idle" then manually call the TN765 port
and transfer the call to appropriate destination, either a
DS1 Trunk Access Code or the data module extension.
See "Link Recovery" if error still occurs. See "Link
Recovery" if error still occurs and link does not establish.
Continued on next page