Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-114test ds1-loop
A
If the extension is not administered, the following message will be displayed:
Extension not assigned
If the object associated with the specified extension is not a data module or a data
channel, the following message will be displayed:
Extension exists but assigned to a different object
If the EPN that contains the data module port is not accessible, the following message
will be displayed:
EPN is not available
If the board that contains the data port is not configured in the system, the following
message will be displayed:
Board not assigned
If no tests can be found for the current MO, the following message will be displayed:
No tests for this MO
If the command entered is in conflict with another currently executing command, then a
message will be displayed showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the user
to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following
message will be displayed:
All maintenance resources busy; try again later
test ds1-loop
Help Messages
If the system technician presses HELP after entering "test ds1-loop" the following
message will be displayed:
Enter DS1 board location,
[’cpe-loopback-jack-test-begin [number-of-bits bit-pattern]’ or
’far-csu-loopback-test-begin’ or ’one-way-span-test-begin’ or
’end-loopback/span-test’ or ’inject-single-bit-error’ or
’ds1/csu-loopback-tests’]