Page 10-688HYB-LINE (Hybrid Line)
10
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension number of the port. Use the status station
command to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain
tests. (Refer to the "Status Commands" section in Chapter 10,
"Maintenance Commands and Trouble-Clearing Aids" for a full description
of all possible states.) You must wait until the port is idle before retesting.
Attendants are always in use (off-hook) if the handset is plugged in and the
port is not busied out.
1. If the port status is idle, then retry the command at one-minute
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 10, "Maintenance Commands and
Trouble-Clearing Aids" for a full description of all possible states.) You
must wait until the port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is not busied out.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-229. TEST #58 Hybrid Line Local Digital Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation