DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-114list mst
8
1. Refer to the Report Scheduler and System Printer feature specification for more details.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
list mst
from message
number
count number
Message number to start the
display; if the number is not in
the buffer, then that is indicated
on the display, and no additional
messages are displayed.
Omitting this qualifier causes
messages to be displayed
starting with the oldest FIFO and
continuous messages.
Message count; can be used to
limit the trace
init
inads
FIFO order See
documen-
tation on the
system
printer
feature.
continuous
Display updates as new
messages enter the trace buffer
(FIFO). This option is most useful
in conjunction with "auto-page."
The command terminates only
when canceled by the user.
LIFO
Newest message displayed first.
FIFO
Messages displayed in the order
received.
[ auto-page ]
The screen will automatically
page when full. Used in
combination with
continuous
(above), provides a way to
"watch" as messages arrive.
print
schedule
Report sent to printer.
Command is validated and then
a scheduling form displays to
schedule execution of the
command. The command is then
placed in the command queue
and is executed at the specified
time. The information displayed
by the command is sent to the
system printer instead of the
screen.
1
Examples:
list mst continuous
list mst continuous auto-page
list mst LIFO
list mst from 222 count 7