Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-194BRI-SET, ASAI-ADJ, BRI-DAT
10
1187 ABORT The circuit pack, port or station may have been busied out by a
technician.
1. Look in the Error Log for Error Type 18 (busied out ) for BRI-BD,
BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then release the station
via the release station command.
a. If this error type is present for BRI-PORT and BRI-SET, then release
the port via the release port PCSSpp command and run the test
again.
b. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then
release the circuit pack via the release port PCSSpp command
and run the test again. If the error is present for BRI-SET only, then
release the circuit pack via the release port PPCSS command
and run the test again. If the error is present for both BRI-BD and
BRI-PORT, then release the circuit pack via the release board
PPCSS command and run the test again.
NOTE:
When you release the circuit pack, you release all ports
associated with it. If certain ports still need to be busied
out, use the release port PCSSpp command to busy
them out.
3. Make sure the terminal is connected.
4. Retry the command at one-minute intervals a maximum of five times.
5. If the test continues to abort, escalate the problem.
2012 ABORT Internal System Error.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-69. TEST #626 Signaling Link Status Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page