DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-461DIOD-DS1 (DS1 DIOD Trunk)
10
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
1281—Loss of signal
1793—Blue Alarm
2049—Red Alarm
2305—Yellow Alarm
1537—Hyperactivity
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
FAIL The trunk cannot be seized for an outgoing call.
1. Verify that the Trunk Type field on the trunk administration screen form
matches the trunk type administered on far end switch.
2. Look for UDS1-BD errors in Hardware Error Log. If present, refer to the
UDS1-BD (DS1/UDS1 Trunk Circuit Pack) Maintenance
documentation.
3. Retry the test at 1-minute intervals for a maximum of 5 times.
4. If the test continues to fail, escalate the problem.
PASS The trunk can be seized for an outgoing call.
Table 10-152. TEST #314 DS1 CO Dial Tone Seizure Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page