DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-1074PRI-CDR/SEC-CDR (PRI-CDR Link)
10
Error Log Entries and Test to Clear Values
Notes:
a. System Technician has busied out the CDR link to out-of-service state.
The CDR link is torn down.
b. Link Retry Test (#215) fails. The Aux Data field contains either the Channel
ID of Data Channels on the TN777 circuit pack (that is, 3 for Channel 01, 4
for Channel 02, 5 for Channel 03, 6 for Channel 04, and 9 for EIA port) or
an Error Code of 99 indicating that no data channels are available for
setting up the link, or an Error Type of 255 indicating an internal system
error. Refer to the preceding ‘‘
Procedures for Restoring the CDR Link’’ for
resolution.
c. The CDR physical link is down due to the following causes: cable to the
CDR output device is disconnected; CDR output device is powered off,
the data extension where the CDR output device connects to has been
busied out or there is a scheduled daily interchange. The Aux Data field
contains the Channel ID of Data Channels on the TN777 circuit pack (that
is, 3 for Channel 01, 4 for Channel 02, 5 for Channel 03, 6 for Channel 04,
and 9 for EIA port). Check the connectivity of wire and cable among wall
jacket, data module, and the CDR output device. Enter status data
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the
set options command.
Table 10-375. CDR Link Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test cdr-link
primary|secondary sh
18 (a) 0 busy out cdr WARNING OFF release cdr-link
primary|secondary
primary|secondary
25 (b) 0
3 to 6
9
99
255
Link Retry Test (#215) MINOR/
WARNING
2
OFF test cdr-link
primary|secondary l
513 (c) 0
3 to 6
9
test cdr-link
primary|secondary
1025 (d)
1281 (e)