Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-324CO-TRK (CO Trunk)
10
1004 ABORT The port has been seized by a user for a valid call. Use status trunk to
determine when the port is available for testing.
1. Retry the command at 1 minute intervals for a maximum of 5 retries.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1005 ABORT Trunk has been administered as incoming-only; transmission tests can
only be run on outgoing trunks.
1115 ABORT The near end test line on the TN771 circuit pack could not be allocated.
1. Verify that the TN771 circuit pack is in service and that port 1 is
administered and in service with the status port command.
2. retry the command at 1 minute intervals for a maximum of 5 retries.
3. If the test continues to abort escalate the problem.
1900 ABORT The test completion message was not received from the TN771 circuit
pack.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
1901 ABORT This error occurs when the TN771 circuit pack uplinks a message that is
not the proper response for this test. The anticipated uplink messages are
seize, ring or answer.
1. Verify that the Trunk is administered properly.
2. If the test continues to abort, escalate the problem.
1905 ABORT Intercept tone detected from far end.
1. Get the test line data from theand verify it with the far end. Dial the test
number manually to see if the TTL is reached. If it is not, then either the
number is wrong, or the far end is administered incorrectly.
2. If the test continues to abort escalate the problem.
1906 ABORT Reorder tone detected from far end.
1. See actions for error code 1905.
1907 ABORT Other unexpected tone detected from far end.
1. See actions for error code 1905.
1913 ABORT Audible Ring detected from far end.
1. See actions for error code 1905.
1914 ABORT Unidentified interrupted tone detected from far end.
1. See actions for error code 1905
Table 10-106. TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page