Lucent Technologies lucent Server User Manual


  Open as PDF
of 2392
 
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Error Messages
Page A-131test packet-control
A
test packet-control
Help Messages
If the system technician presses HELP after entering "test packet-control", the following
message is displayed:
Enter [cabinet(1)]; carrier (A-B),
[’long’ or ’short’], [’repeat’ (1-100)
or ’clear’], [’schedule’]
Error Messages
If this command is executed on the standby SPE and this SPE is busy at the moment, the
following will be displayed:
Standby SPE busy;
See status system for more details
If during the execution of a command a resource problem occurs that requires the user
to restart the command, then the following message is displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the following
message will be displayed:
All maintenance resources busy; try again later
test pkt
Help Messages
If the system technician presses HELP after entering "test pkt" the following message will
be displayed:
Enter ’port-network’, port network number (1-3),
[’long’ or ’short’], [’repeat’ (1-100)
or ’clear’], [’schedule’]
Error Messages
If the technician does not enter all digits for the port-network number, the following
message will be displayed:
Entry must be all digits
If the port network on which the desired Packet bus resides is unavailable, the following
message will be displayed:
EPN is not available