DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si
555-230-127
Issue 1
August 1997
Maintenance Object Repair Procedures
Page 10-843MODEM-PT (Modem Pool Port)
10
Modem Pool Audit Test (#99)
This audit updates the Modem Pool conversion resource status contained in the
TN758 Pooled Modem circuit pack’s microprocessor. It does not actually test the
Pooled Modem circuit pack; therefore, there are no FAIL codes. The audit can
only be performed on idle conversion resources. If the conversion resource is in
use, the audit aborts.
5012 ABORT The digital portion of the tested Modem Pool Port did not disconnect
properly.
1. Follow the repair procedures for Error Code 5000.
5013 FAIL The Modem Pool Port did not respond with an on-hook message when the
connection to the Data Channel was broken, indicating a likely problem
with the TN758 Pooled Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
5014 ABORT The Network Control Channel allocated for this test did not respond
correctly to the setup message sent to it after the connection was
established.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit pack using the test
data-module command (refer to the DATA-CHL maintenance
strategy).
3. If the DATA-CHL circuit pack tests pass, escalate the problem.
5015 ABORT Data Channels 1 and/or 3 have not been administered.
1. Administer the Data Channels and retest.
Table 10-280. TEST #98 Modem Pool Conversion Resource Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page