DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-66ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
10
reported as part of the Common Port Circuit Pack errors (see errors 1281 and
1793 in the XXX-BD (Common Port Circuit Pack) Maintenance documentation).
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. These are in-line errors and can only be resolved over time.
40960indicates that too many simultaneous incoming ringing
attempts were made on this board. Only four ports on a board may
be ringing simultaneously. A fifth incoming call will cause an inline
error from the board.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used
in the set options command.
Table 10-26. 8-Port Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40960
40975
40977
None
15 (b) Any Audits and Updates
Test (#36)
18 0 busyout station
<extension>
WRN OFF release station <extension>
130(c) None WRN ON test port PCSSpp sh
257 (d) Station Present Test
(#48)
WRN OFF test port PCSSpp sh r 3
513 Battery Feed Test
(#35)
MIN/
WRN
2
ON test port PCSSpp sh r 2
769 (e) Loop Around and
Conference Test(#47)
test port PCSSpp l r 3
1025 NPE Crosstalk Test
(#6)
MIN/WR
N
2
ON test port PCSSpp l r 3
1281 (f)
1793 (f)