DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1675XXX-BD (Common Port Circuit Pack)
10
Ringing Application Test (#51)
This test checks the ringing application circuitry common to all ports on an
Analog Line circuit pack.
Table 10-493. TEST #51 Ringing Application Circuit Test
Error
Code
Test
Result Description/ Recommendation
1000 or
2100
ABORT Could not allocate the necessary system resources to
run test.
ABORT Could not allocate the necessary system resources to
run test. The circuit pack is not installed. Internal System
Error.
2000 ABORT There was no response from the board.
1. If error type 1538 (hyperactivity) is present in the
error log, follow the maintenance strategy that is
recommended for this error type.
2. Run the busyout board, reset board, and release
busy board commands,and then retest.
3. If the test still aborts, dispatch with the circuit pack.
4. Check the off-board wiring and the terminal, and, if
there are no problems found, replace the circuit
pack.
1004 ABORT The port was seized by a valid call during the test. The
test has been aborted. Use the display port PCSSpp
command to determine the station extension. Use the
status station command to determine the service state
of the port. If the service state indicates that the port is in
use, the port is unavailable for certain tests. (Refer to the
"Status Commands" section in Chapter 8, ‘‘
Maintenance
Commands and Trouble-Clearing Aids’’ for a full
description of all possible states.) You must wait until the
port is idle before retesting.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort and the port is idle,
escalate the problem.
Continued on next page