Page 10-80ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
10
1005 ABORT The test was aborted due to a configuration problem. This code will result
under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to terminal
equipment other than a voice terminal (for example, the modem pool
member or music on hold).
2. The circuit pack is one of the following:
— TN742 vintages 13,14 and 15
— TN769 vintages 3,4 and 5
1018 ABORT Test disabled via administration. The default for the 'Test' field on the
'Station' form is 'y'; thus, you may want to determine why this field has been
set to 'n' on this station (this may be due to the ringing application test 48,
which can be customer or terminal disturbing).
1. To enable the test for a particular station, enter change station
extension and set the ‘Test?’ field on the ‘Station Form’ to ‘y.’
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available. Either a system
allocation to get information about the port or to put the port into a service
state failed or the attempt to put the port in connection with a tone source
failed (this could be a tone-clock problem). The tone-clock and tone
detectors could be having a communication problem, for example, the
companding modes could be out of synchronization.
1. Retry the command at 1-minute intervals a maximum of 5 times.
7 FAIL The conference test or the noise test failed. This could cause noisy or
unreliable connections, or users calling this port may hear an echo. The
problem can also be off-board, as described below.
13 The reflective loop around with gain set to low and the 600-ohm balance
failed. This will cause noisy or unreliable connections.
14 The reflective loop around test (with the gain set to high, using RC balance)
failed. This could cause noisy or unreliable connections. The problem can
also be off-board, as described below.
15 The nonreflective loop around test failed. This could cause noisy or
unreliable connections, or users calling this port may hear an echo. The
problem can also be off-board, as described below.
More information continues on the next page.
Table 10-30. TEST #47 Loop Around and Conference Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page