DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-111ANN-PT (Announcement Port)
10
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
b. This error is logged and the port is alarmed when an alarm is raised on the
Announcement circuit pack because of a faulty condition with a common
circuit pack resource. Any one of the following alarmed errors on the
Announcement circuit pack causes this error to be logged against the
Announcement Port: 1793, 2049, 2305, 2561. Follow the ANN-BD
(Announcement Circuit Pack) Maintenance documentation to resolve
these alarms. When the corresponding circuit pack alarm is cleared, this
alarm clears.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
Announcement Port Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 Playback Speech Memory
Array (PSMA) Test (#206)
MINOR ON test port PCSSpp sh r 3
18 0 The port was busied out WARNING OFF release port PCSSpp
130 (a) None WARNING ON test port PCSSpp sh
257 Channel Administration
Memory Array (CAMA)
Test (#205)
MINOR ON test port PCSSpp l r 3
17667 In-line error
513 140AY Channel Sanity
Inquiry Test (#222)
MINOR ON test port PCSSpp sh r 3
17684 In-line error
769 (b) None