Maintenance Commands and Trouble-Clearing Aids
Page 8-29busyout port
8
Parameters
Help Messages
If the system technician presses HELP after entering "busyout port," the following
message will be displayed:
Enter 7 character port number
Error Messages
If the format of the port location is incorrect, the following error message will be
displayed:
Port/Board invalid
If the EPN on which the port resides is unavailable, the following message will be
displayed:
EPN is not available
If the board on which the port resides is not administered, the following error
message will be displayed:
Port not assigned
If the board on which the port resides is part of the SCI link, the following error
message will be displayed:
Cannot busyout/release part of SCI link
If the port is translated within a Wideband Access Endpoint, the following error
message will be displayed:
Port within wideband access endpt; Use busyout access-endpoint <ext> instead
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
location A "location" represents the physical position of the port to be
busied out and is entered as "UUcSSpp" where "UU" represents
the cabinet number (1-3), "c" represents the carrier, "SS"
represents the slot position, and "pp" represents the circuit
(port).
A "location" represents the physical position of the port to be
marked and is entered as "PCSSpp" where P is the port network
number (1 for PPN, 2 for EPN, and 3 for the second EPN); C is
the carrier designation (for example, A, B, C, D, or E); and SS is
the address of the slot in the carrier where the circuit pack is
located (for example, 01, 02, ...etc.), and "pp" represents the
circuit (port). A single digit cabinet (1 - 3) may be entered with
or without a leading zero (0).