Maintenance Object Repair Procedures
Page 10-487DIG-LINE (Digital Line)
10
EFP and PPF is that, if the port goes into a overcurrent state, PPF does not report
this change of state because it is a transient state which will not last more than
50ms. If the over current persists the power will be shut off automatically and an
EPF_off_overcurrent message is sent uplink.
Table 10-131. TEST #11 Digital Line Electronic Power Feed Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available. The port may be busy with a valid call. Use
display port UUCSSpp/PCSSpp to determine the station
extension or attendant number of the port. Use status
station or status attendant to determine the service
state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain
tests. (See Chapter 10, "Maintenance Commands and
Trouble-Clearing Aids", for a full description of all
possible states.) You must wait until the port is idle
before retesting. Attendants are always in use (off-hook)
if the handset is plugged in and the port is not busied
out.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL Internal System Error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
Continued on next page