DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-579test eda-external-device-alrm
8
Output
For the following output example the command that was entered was "test
external-device-alarm all":
The responses will be displayed on a test-by-test basis with one line of data
displayed for each test result.
Field definitions:
Port The port address (cabinet-carrier-slot-circuit) of the maintenance object
that is being tested.
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name The alternate means of identifying the maintenance object. This is an
administered more descriptive name of the external device alarm
Test No The actual test that is being executed.
Result The result of the individual test -"PASS", "ABORT", "FAIL",
"NO BOARD", "DISABLED", "EXTRA BD".
Error Code A system-generated number that tells why the release failed or aborted.
A detailed list of the codes according to "Test No." is provided for each
MO.
test eda-external-device-alrm all
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
03major EXT-DEV CMS1 120 PASS
03A2102 EXT_DEV CMS2 120 FAIL
01major EXT-DEV UPS1 120 PASS
01minor EXT-DEV UPS1 120 PASS
01c1201 EXT-DEV UPS1 120 PASS
03A2101 EXT_DEV CC temp 120 PASS
01c1202 EXT-DEV Audix1 120 PASS
03minor EXT-DEV Audix2 120 FAIL
04major EXT-DEV unknown 120 FAIL
Command successfully completed