DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Routine Maintenance Procedures
Page 5-22Software Upgrade
5
NOTE:
The save translation command cannot function if the translation corruption
message appears.
Disable TTI
Enter change system-parameters features and press Enter. Use Page 2 of the
form to disable Terminal Translation Initialization (TTI) by changing the value to n.
List Configuration Software Version
Issue the list configuration software-versions command to determine if any
patches have been applied.
NOTE:
If the system must be restored to the old software, download the correct
patches.
Disable Scheduled Maintenance
Enter change system-parameters maintenance, and press Enter. Use this form
to prevent scheduled daily maintenance from interfering with the update or
upgrade.
NOTE:
If scheduled maintenance has begun, set the value of the “Stop Time” field
to 1 minute after the current time. If scheduled maintenance has not yet
begun, change the value of the “Start Time” field to a time after the upgrade
is finished.
Disable Alarm Origination to INADS
1. Enter change system-parameters maintenance and press Enter.
2. Enter n in the
Alarm Origination
field and press Enter.
3. For some releases of system software, disable
Cleared Alarm Notification
and
Restart Notification
before submitting the form.
!
CAUTION:
Disabling alarm origination prevents the system from generating
alarms, thus preventing unnecessary trouble tickets.
Save Announcements
1. If the system is equipped with a TN750/B Announcement circuit pack,
enter display announcements, and press
Enter. If administered recorded
announcements are listed, enter save announcements [from PCSS] and