DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1471TIE-TRK (Tie Trunk)
10
Table 10-446. TEST #74 Tie Trunk EPF Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to
run the test. This could be due to a failure to seize the
port.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
1 ABORT Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available. The trunk may be busy with a valid call. Use
the display trunk xx to determine trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service
state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port
is idle before retesting.
1. If the port status is active, but the port is not in use
(no calls), then check the Error Log for Error Type
1025 (see Error Log table for description of this error
and required actions). The port may be locked up.
The far-end PBX may not be releasing.
2. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
3. If the test continues to abort, escalate the problem.
Continued on next page