DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-20ADX8D-BD (AUDIX Circuit Pack)
10
ADX8D-BD (AUDIX Circuit Pack)
The ADX8D-BD maintenance object represents a TN566/TN2169 DEFINITY
AUDIX circuit pack (sometimes called Embedded AUDIX) operating in
digital-port (DP) mode. For circuit pack problems, see “XXX-BD (Common Port
Circuit Pack)”. Port level problems are covered by ADX8D-PT.
DEFINITY AUDIX
consists of two circuit packs that occupy 5 slots on a port
cabinet. The tests described in this manual apply only to switch-side
maintenance which tests circuit pack components related to the TDM bus
interface. The AUDIX system has an extensive maintenance strategy that is
described in
DEFINITY AUDIX System Maintenance
, 585-300-110.
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs).
C
is the carrier designation
(A, B, C, D, or E).
SS
is the number of the slot in which the circuit pack resides (01 to 21).
MO Name (in
Alarm Log) Alarm Level Initial Command To Run
1
Full Name of MO
ADX8D-BD MINOR or
WARNINGS
test board PCSS sh AUDIX Circuit Pack