DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1158PR-MAINT (Maintenance Processor)
10
1131 ABORT INADS port is busy because the system is reporting alarms to INADS, or
because INADS is dialed into the system.
1. Wait about ten minutes and then re-enter the command.
10201 ABORT System software resources required to run this test are not available.
10202 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
10203 ABORT MTP did not respond to the test request.
1. Repeat the test at 1-minute intervals a maximum of 5 times.
2. If all MTP tests are aborting, execute the test processor a/b long
command in order to reset MTP and to examine the results of the MTP
Reset Test (#101).
3. Replace the Processor circuit pack.
4. If only the MTP outpulse relay test is aborting, escalate the problem.
10204 FAIL MTP reported test failure. No loop current detected.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, examine the INADS trunk for connectivity,
and manually check for loop current.
3. If there is no INADS trunk, this test should be disabled. To disable the
test, issue the change system-parameters maintenance command,
and change the Test Remote Access Port field to "n." If this test is failing
on the Standby SPE, issue the refresh spe-standby command, and
rerun the test.
4. If the INADS trunk checks out okay, but the test still fails, check the
backplane connector wiring.
5. If the backplane wiring checks out okay, replace the Processor circuit
pack at your earliest convenience.
PASS MTP detected a loop current on the remote access port.
1. If the system cannot call INADS, or INADS cannot contact the system,
check with the local Central Office for problems with the INADS trunk,
and verify that the INADS number is correct.
10205 ABORT Internal system error
1. Retryt the command at 1-minute intervals a maximum of 5 times.
Table 10-346. TEST #102 MTP Outpulse Relay Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page