Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-595test inads-link
8
System Interaction
The performance of "test hardware-group" is affected by call processing traffic,
administration activity, choice of the ’short’ or ’long’ option, whether the ’all-ports’
option was chosen, whether the ’spe-interchange’ option was chosen, and other
demand maintenance activity.
Scheduled and Periodic maintenance
When a "test hardware-group" command is entered, all activity related to
scheduled background maintenance, periodic background maintenance, and
data audits is suspended for the duration of the execution of the "test
hardware-group" command. When a "test hardware-group" command is
canceled or when the "test hardware-group" command completes, all suspended
periodic, scheduled, and data audits background maintenance activity will be
restarted where it left off.
test inads-link
This command will perform hardware diagnostic tests from the inads port that is
accessible through the maintenance board to an OSS telephone number.
Synopsis
test inads-link [1 | 2]
Permissions
The following default logins may execute this command: system technician,
inads, init, nms.
Examples
test inads-link
test inads-link 1
test inads-link 2
Description
The test inads-link command attempts to make a call over the inads port on the
maintenance board to verify the INADS alarm notification process. By default, the
link to the first OSS telephone number is tested. If there is an alarm pending to be
reported or the call is in progress or up, then the test will be aborted. If the alarm
origination to the OSS telephone number to be tested is disabled, the test
generates an informative error and the test continues. The test will wait 2 minutes
before executing to allow the remote maintenance technician to logoff freeing the