DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-461status interface
8
Description
The status interface command displays the current value of a number of counters
maintained by the PI, which is a front end processor implementing the packet
layer and link layer of the BX.25 protocol and the integrated services digital
network (ISDN) procedure-D protocol.
Defaults
The cabinet number defaults to one (1) if it is not specified.
Parameters
Help Messages
If the system technician presses HELP after entering "status interface", the
following message will be displayed:
Enter location: [cabinet(1)], carrier (A-B),
position(1-2); [’print’]
Error Messages
If the specified carrier is not the active PE, the following message will be
displayed:
Port invalid
If the technician-entered cabinet and carrier is invalid for a PPN, the following
message will be displayed:
Entry is bad
If the technician-entered carrier is not a valid carrier, the following message will
be displayed:
Invalid carrier specified
If the technician-entered carrier is not active, the following error message will be
entered:
Board invalid
location The location (cabinet-carrier-position) of the processor interface (PI
board). A position of 1 is the first processor interface in the carrier,
while a position of 2 is the second processor interface in the carrier.
print This will cause the report to be printed if a printer is linked to the
SAT.