Maintenance Object Repair Procedures
Page 10-480DIG-LINE (Digital Line)
10
1004 ABORT The port was seized by a valid call during the test. The
test has been aborted. Use the display portUUCSSpp
command to determine the station extension or
attendant number of the port. Use status station or
status attendant to determine the service state of the
port. If the service state indicates that the port is in use,
then the port is unavailable for certain test. (See Chapter
10, "Maintenance Commands and Trouble-Clearing
Aids", for a full description of all possible states.) You
must wait until the port is idle before resetting.
Attendants are always in use (off-hook) if the handset is
plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort and the port is not in
use, escalate the problem.
1005 ABORT The installed circuit pack does not support this
operation.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
2100 ABORT System resources required to run this test are not
available.
1. Make sure terminal is connected and repeat test.
2. If the test continues to abort, escalate the problem.
3. If test fails replace terminal and repeat test.
4. Retry the command at 1-minute intervals a maximum
of 5 times.