DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-722FL-DATA (Flash Data Consistency)
10
9005 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
35498 ABORT Difficulty was encountered trying to send information between the
SPEs.
35512 ABORT The Standby SPE cannot be put into maintenance mode.
1. Check for and resolve all DUPINT (Duplication Interface Circuit
Pack), SHDW-LNK (Memory Shadowing Link), SHDW-CIR
(Common Shadow Circuit), and STBY-SPE (Standby SPE) alarms.
2. Retry the command.
35514 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
35534 ABORT Could not allocate the (active or standby) memory card drive
because another memory card operation was in progress.
1. Wait 10 minutes, and retry the command.
35535 ABORT Could not access the (active or standby) memory card.
1. The memory card may be damaged or missing. Resolve all
problems with all memory card tests in the Long Test Sequence
for both memory cards.
2. Repeat the test.
1 FAIL The standby translations are out-of-date. The translations on the
Standby SPE (memory card) are older than those on the Active SPE
(memory card).
2 FAIL The Active SPE translations are out-of-date.
1. Issue save translations command. If the translation save passes
on both SPEs, go to Step 2.
2. Run test card-mem long again to resolve the alarms.
Table 10-205. TEST #421 Flash Data Consistency Check Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page