DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-927MODEM-PT (Modem Pool Port)
10
Modem Pool Audit Test (#99)
This audit updates the Modem Pool conversion resource status contained in the
TN758 Pooled Modem circuit pack’s microprocessor. It does not actually test the
Pooled Modem circuit pack; therefore, there are no FAIL codes. The audit can
only be performed on idle conversion resources. If the conversion resource is in
use, the audit aborts.
5013 FAIL The Modem Pool Port did not respond with an on-hook
message when the connection to the Data Channel was
broken, indicating a likely problem with the TN758
Pooled Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
5014 ABORT The Network Control Channel allocated for this test did
not respond correctly to the setup message sent to it
after the connection was established.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit
pack using the test data-module command (refer to
the DATA-CHL maintenance strategy).
3. If the DATA-CHL circuit pack tests pass, escalate
the problem.
5015 ABORT Data Channels 1 and/or 3 have not been administered.
1. Administer the Data Channels and retest.
Table 10-262. TEST #98 Modem Pool Conversion Resource Loop Around
Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page