Maintenance Commands and Trouble-Clearing Aids
Page 8-163enable suspend-alm-orig
8
Help Messages
If you press Help after entering "enable mst", the following message displays:
Entry is not required
Error Messages
If the command conflicts with another currently executing command, a message
displays the login ID of the conflicting user and the conflicting command.
’login id’:’command’ has a command conflict
Output
After you enter the command the following message displays:
Command successfully completed
Feature Interactions
None.
enable suspend-alm-orig
This command suspends Alarm Origination for alarms generated from a
specified hardware component over a time-out duration.
Synopsis
enable suspend-alm-orig (board or port location) [off-board-only]
expires-in-hrs(1-72).
Examples
enable suspend-alm-orig 1C03 expires-in-hrs 3
enable suspend-alm-orig 1E0701 expires-in-hrs 72
enable suspend-alm-orig 1E07 off-board-only expires-in-hrs 24
Description
This command enables Suspend Alarm Origination for a board (which also
includes all ports and endpoints on the board) or for a port (which includes all
endpoints on the port), and either for both on- and off-board alarms or for
off-board alarms only. Many control circuit packs do not have a board location,
so this command cannot support all circuit packs.