Routine Maintenance Procedures
Page 5-35Software Upgrade
5
NOTE:
The TN750C Announcement circuit pack has on-board non-volatile
storage and does not need to be saved to the translation card.
Enable TTI
If TTI was enabled prior to the software upgrade:
1. Enter change system-parameters features and press
Enter.
2. Use page 2 of the form to change the TTI field back to y (if necessary).
Enable Scheduled Maintenance
Enter change system-parameters maintenance, and press Enter. Use this form
to enable scheduled daily maintenance.
Enable Customer Options
1. Enter change system-parameters customer-options and press Enter.
2. Use these forms to verify the customer options are properly set.
NOTE:
In the Basic Call Setup field, if ISDN-PRI? was set to y before the
upgrade, be sure to set the field back to y.
Resolve Alarms
Examine the alarm log. Resolve any alarms that may exist using
DEFINITY
Enterprise Communications Server Release 5.4 Maintenance for R5vs/si
.
Verify Alarm Origination to INADS
Be sure the system is part of the existing INADS database by calling the INADS
Database Administrator at the Technical Service Center (TSC). Verify that INADS
can dial into the system and that the system can dial out to INADS.
As part of the system registration process, the INADS Database Administrator
enables Alarm Origination.
Return Equipment
Return the replaced equipment (including the old Translation Card) to Lucent
Technologies according to the requirements outlined in the following documents:
BCS/Material Logistics, MSL/Attended Stocking Locations
Methods and Procedures for Basic Material Returns