DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-353CO-TRK (CO Trunk)
10
Port Audit Update Test (#36)
This test sends updates of the CO port translation for all ports on the circuit pack
that have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the circuit pack. No
response message is expected from the circuit pack once it receives translation
updates. The port translation data includes: ground or loop start trunk, tone or
rotary dialing trunk, rotary dialing inter-digit timing, network balance R/RC, and
disconnect timing.
Table 10-98. TEST #36 Port Audit Update Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
1006 ABORT The port has been placed out of service, perhaps by
craft busyout. Use the display port UUCSSpp
command to determine the trunk group/member number
of the port. Use the status trunk command to determine
the service state of the port. If the service state indicates
that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1
minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
2100 ABORT System resources required to run this test were not
available.
1. If the port status is idle, retry the command at 1
minute intervals for a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL Internal system error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If test continues to fail, escalate the problem.
Continued on next page