Table 10-212. TEST #60 Hybrid Line Lamp Updates Test
Error
Code
Test
Result Description/ Recommendation
1 ABORT A request for a remote station lamp update aborted
even though all internal resources were correctly
allocated.
1. Look in the error log for error type 18 (port busied
out) for this port. If this error type is present, release
the port via the release port UUCSSpp command or
the release station extension command, and then
run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals for a
maximum of 5 times.
4. If the test continues to abort, escalate the problem.
2 ABORT Internal System Error.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.
3 ABORT The station is in a ready for service or an out of service
state. This may be due to wiring or an unplugged or
defective set.
1. Make sure terminal is connected and the wiring is
correct.
2. Retry the command at 1-minute intervals a maximum
of 5 times.
3. If the test continues to abort, escalate the problem.
Continued on next page