Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-356CO-TRK (CO Trunk)
10
1004 ABORT The port has been seized by a user for a valid call. Use
status trunk to determine when the port is available for
testing.
1. Retry the command at 1 minute intervals for a
maximum of 5 retries.
2. If the test continues to abort and the port is not in
use, escalate the problem.
1005 ABORT Trunk has been administered as incoming-only;
transmission tests can only be run on outgoing trunks.
1115 ABORT The near end test line on the TN771 circuit pack could
not be allocated.
1. Verify that the TN771 circuit pack is in service and
that port 1 is administered and in service with the
status port command.
2. retry the command at 1 minute intervals for a
maximum of 5 retries.
3. If the test continues to abort escalate the problem.
1900 ABORT The test completion message was not received from the
TN771 circuit pack.
1. Test the TN771 circuit packs.
2. If the test continues to abort escalate the problem.
1901 ABORT This error occurs when the TN771 circuit pack uplinks a
message that is not the proper response for this test.
The anticipated uplink messages are seize, ring or
answer.
1. Verify that the Trunk is administered properly.
2. If the test continues to abort, escalate the problem.
1905 ABORT Intercept tone detected from far end.
1. Get the test line data from theand verify it with the far
end. Dial the test number manually to see if the TTL
is reached. If it is not, then either the number is
wrong, or the far end is administered incorrectly.
2. If the test continues to abort escalate the problem.
Table 10-99. TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page