DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1021PDMODULE, TDMODULE (Data Module)
10
1071 ABORT No auxiliary port on Netcon circuit pack available to test
with.
1. Check that the Netcon data channels are
administered (the list data-modules command
should show at least one Netcon-type data module).
2. Test the Network Control (Netcon) circuit pack using
the test data-module command for the Netcon
circuit pack.
3. If administration data is correct, escalate the
problem.
2000 ABORT Data module disconnected.
1. Verify that the data module is powered (power LED
on).
2. Make sure data module is connected to the building
wiring. Check for faulty wiring and faulty data
module.
3. Retry the command at one-minute intervals a
maximum of five times.
4. Replace the Data Module and repeat the test.
5. If the test continues to abort, replace the Digital Line
circuit pack and repeat the test.
6. If the test continues to abort, escalate the problem.
2500 ABORT Internal System Error.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to fail, escalate the problem.
Table 10-292. TEST #175 Data Module Internal
Loop Around Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page