DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1644VC-DSPPT
10
Table 10-481. TEST #1104 VC DSPPT Local
TDM Loopback Test
Error
Code
Test
Result Description/Recommendation
1000
1001
ABORT System resources required to run this test are not available, or the port is
busy with a valid call.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The traffic load on the
system is very high, or time slots may be out-of-service due to TDM-BUS
errors. Refer to “TDM-BUS” to diagnose TDM Bus errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a Tone Detector for the test. The system is
oversized for the number of Tone Detectors present, or some Tone
Detectors are out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors.
3. If neither condition exists, retry the test at 1-minute intervals.
1004 ABORT The port is seized by a user for a valid call. Use the status station
command for the station associated with this port and determine if the port
is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test was not received from the VC-BD circuit pack within
the allowable time period.
1. If this result occurs repeatedly, attempt to reset the port by using the
busyout port PCSSpp and reset port PCSSpp commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2100 ABORT Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
0-3 FAIL The TDM Loop Around Test failed.
1. Replace circuit pack.
4-7 FAIL The Conference Circuit Test failed.
1. Replace circuit pack.
Continued on next page