DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-6busyout board
8
Parameters
Help Messages
If the system technician presses HELP after entering "busyout board," the
following message will be displayed:
Enter 5 character board number
Error Messages
If the format of the board location is incorrect, the following error message will be
displayed:
Port/Board invalid
If the EPN on which the board resides is not available, the following message will
be displayed:
EPN is not available
If a board is not inserted in the specified location, the following message will be
displayed:
Board not assigned
If the specified board does not have any maintenance objects associated with it,
the following message will be displayed:
No MO in this board
If the specified board is part of the DCS link, the board cannot be busied out
unless the link itself is busied out first. If the DCS link is not busied out, the
following message will be displayed:
Must first busyout SCI link
If the specified board is an EI board and it is part of the active link, the following
message will be displayed:
Illegal Command for active object; use ’set’ to switch to standby
location A "location" represents the physical position of the board to be busied
out and is entered as "UUcSS" where "UU" represents the cabinet
number (1-3), "c" represents the carrier, and "SS" represents the slot
position.
A "location" represents the physical position of the port to be marked
and is entered as "PCSSpp" where P is the port network number (1 for
PPN, 2 for EPN, and 3 for the second EPN); C is the carrier designation
(for example, A, B, C, D, or E); and SS is the address of the slot in the
carrier where the circuit pack is located (for example, 01, 02, ...etc.),
and "pp" represents the circuit (port). A single digit cabinet (1 - 3) may
be entered with or without a leading zero (0).