Maintenance Object Repair Procedures
Page 10-506DIOD-DS1 (DS1 DIOD Trunk)
10
Table 10-136. TEST #7 Conference Circuit Test
Error
Code
Test
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available. The port may be in use on a valid call. Use the
status station or status trunk command to determine
when the port is available for testing.
1004 ABORT The port has been seized by a user for a valid call. Use
the status station or status trunk command to
determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, and the port is not in
use, escalate the problem.
1018 ABORT Test disabled via administration. This only applies to
analog stations.
1. To enable test, set the Test field on the station
administration screen for the particular analog
station being tested to ‘‘y.’’ Use the change station
extension command.
1020 ABORT The test did not run due to a previously existing error on
the specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this
port or the circuit pack and attempt to diagnose the
previously existing error.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.