Lucent Technologies R5SI Computer Hardware User Manual


  Open as PDF
of 2643
 
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1320SW-CTL (Switch Control)
10
Table 10-399. TEST #95 Time of Day Clock Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT The test was interrupted by a higher priority task.
1. Rerun the test at 1-minute intervals a maximum of 5 times.
2. If the test aborts five times, wait until the system is less heavily used and
rerun the test at that time.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT Refer to STBY-SPE for a description of these error codes.
2012 ABORT Internal system error
2013 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2001 FAIL The Time of Day clock could not be read.
1. Run the set time command and set the time to the current time.
2. Run the Short Test Sequence several times to determine if setting the
time corrected the error. Proceed to Step 3 if the error is still occurring.
3. Replace the Netcon circuit pack at the customer’s convenience
(Standard system) or right away (High or Critical Reliability system).
other FAIL The accuracy of Time of Day clock is not within limits.
1. Run the Short Test Sequence several times to make sure the error is
occurring consistently.
2. Replace the Network Control (DATA-BD) circuit pack at the customer’s
convenience (unduplicated system) or right away (High or Critical
Reliability system).
3. The procedure for replacing the Network Control (DATA-BD) circuit
pack is described in Chapter 6, ‘‘
Reliability Systems: A Maintenance
Aid’’. The procedure for doing the same in systems without High or
Critical Reliability is described in Chapter 5, ‘‘
Routine Maintenance
Procedures’’.
PASS The Time of Day clock on the Switch Control circuit pack is operating
correctly.
Continued on next page