DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-79ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)
10
1000 ABORT System resources required to run this test were not available. The port may
be busy with a valid call. (This could be a Music-on-Hold port.)
1. Enter display port PCSSpp to determine the station’s extension. Enter
status station extension to determine the service state of the port. If
the port is in use, it will be unavailable for certain tests. Wait until the
port is idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Refer to "TDM-BUS (TDM Bus)" Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at one-minute intervals a maximum of five times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to "TTR-LEV
(TTR Level)" Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to "TONE-PT
(Tone Generator)" Maintenance documentation.
3. If neither condition exists, retry the test at one-minute intervals a
maximum of five times.
1004 ABORT The port has been seized for a valid call during the conference or noise
test. Use the status station command to determine when the port is
available for testing.
1. If the circuit pack is a TN742 with vintage 10 or less, this test is not
valid. Otherwise, proceed with #2.
2. When the port is available for testing, retry the command at 1-minute
intervals, a maximum of 5 times.
3. If the test continues to abort and the port is not in use, escalate the
problem.
Table 10-30. TEST #47 Loop Around and Conference Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page