DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-317reset board
8
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
All maintenance resources busy; try again later
Output
For the following output example, assume that the board in port network 1, carrier
c, slot 7 is an analog board with three ports administered. The command that
was entered is "reset board 1c07."
Feature Interactions
None.
Port The port address (cabinet-carrier-slot) of the maintenance object
that is being reset.
Maintenance Name The type of maintenance object being reset.
Alt. Name The alternate means of identifying the maintenance object. This
field contains the extension when the object is a station, and it
contains xxx/yyy when the object is a trunk, where xxx is the trunk
group number and yyy is the member number. It contains P/xxx
when the object is a private CO line, where xxx is the private CO
line group number.
Result The result of the reset -"PASS," "ABORT," "FAIL."
Error Code A system-generated number that tells why the reset failed or
aborted. A detailed list of the codes can be in the "Reset
Commands" section of this chapter.
reset board 1C07
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C07 ANL-BD 53 PASS
Command Successfully Completed